Sound insulation

When building external and internal partitions made from SOLBET autoclaved aerated concrete, it is possible to achieve walls which meet the standard requirements concerning acoustic insulation for such partitions.

The acoustic insulation is related to the mass of the partitions and depends, for example, on the thickness of the blocks and the autoclaved aerated concrete variety used. Heavier partitions give better acoustic insulation. By choosing SOLBET autoclaved aerated concrete partition walls, it is possible to achieve partitions which meet the standard requirements concerning sound insulation for such partitions. Exterior walls made from autoclaved aerated concrete, which meet the thermal insulation requirements, will also effectively protect interiors from unwanted sounds, meeting the sound insulation standards for most building locations.

Sound insulation index

Specific sound insulation indexes ratings RA1R and RA2R [dB] for masonry walls made of SOLBET blocks, depending on wall thickness

Gęstość
brutto [kg/m3]

Gross density [kg/m3]Value RA1R index for internal walls

Value
RA2R index for external walls


60

80

100

120

180

240

300

360

420

60

80

100

120

180

240

300

360

420

400

 

 

 

 

 

41

44

46

48

 

 

 

 

 

38

40

42

44

500

 

 

 

36

41

44

46

48

 

 

 

 

34

37

40

42

45

 

600

33

34

36

38

43

46

48

50

 

32

33

34

35

39

42

45

47

 

700

 

 

 

40

 

48

 

 

 

 

 

 

36

 

44